Hezhong Zhida photoelectric direct reading long-distance water meter uses photoelectric direct reading technology to directly read the word wheel data. Compared with traditional pulsed water meter, the reading error can be reduced to zero. It is an electronic long-distance water meter with zero error in mechanical and electrical conversion in the automatic meter reading system. With a low-power design, there is no need to supply power at ordinary times, and it only needs to be supplied to it when reading the meter.
1. It meets the standard of Electronic Long-distance Water Meter (CJ/T224-2012).
2. Comply with the national standard of Drinking Cold Water Meter and Hot Water Meter (GB/T778.13-2007).
3. Working power supply: DC9-15V (RS485); DC24-42V (M-BUS).
4. Adopt advanced data coding and verification methods, and have high communication reliability.
5. It meets the technical requirements of electromagnetic compatibility of electronic products such as EMC, ESD and EMI, and is at a relatively high level in the industry.
6. Communication regulations: DL/T645, CJ/T188, MODBUS, industry general standard protocol.
7. Communication interface: a) RS485 fieldbus, b) M-BUS fieldbus.
8. Communication transmission rate: 1200bps/2400bps.
9. It is easy to read and can be kept clear for a long time.
10. Adopt the energy-free direct reading technology of photoelectric coding.
11. Adopt non-contact sensors, which does not affect the performance of the water meter.
12. With a low-power design, power supply is only required when reading.
13. It can form a system with the upper computer to realize remote meter reading.
Signal wiring
| Type/line color | Red line | Black line | White (yellow) line | Blue (green) line |
| 485/Bus | The power supply is positive | Power supply negative | 485+ | 485- |
| M-BUS bus | No polarity | No polarity |
Technical Specifications
| 公称口径(DN) | Nominal Diameter | Common Traffic | Minimum Reading | Maximum Reading | Accuracy Level |
| mm | Q3/Q1=80、63、50 | m³/h | m³ | m³ | Level 2 |
| 15 | 2.5 | 0.0001 | 9999 | ||
| 20 | 4 | 0.0001 | 9999 | ||
| 25 | 6.3 | 0.0001 | 9999 | ||
| 32 | 10 | 0.0001 | 9999 | ||
| 40 | 16 | 0.0001 | 9999 | ||
| 50 | 50 | 0.0001 | 9999 |
Installation Diagram And Dimensions Of Horizontal Direct Reading Remote Transmission Meter
| Nominal Diameter(DN) | Length(mm) | Width(mm) | Height(mm) | Threaded Connection | Weight(kg) |
| 15 | 165 | 98 | 104 | G/4B | 1.5 |
| 20 | 190 | 98 | 106 | G1/B | 1.7 |
| 25 | 225 | 103 | 112 | G1’1/4B | 2.4 |
| 32 | 230 | 104 | 117 | G1’1/2B | 4.5 |
| 40 | 245 | 124 | 147 | G2/B | 4.8 |
| 50 | 285 | 160 | 195 |