4G single-phase 4P rail smart meter, used for measuring AC single-phase active energy with a rated frequency of 50Hz, can achieve the management function of paying before using electricity. This product is manufactured using internationally advanced specialized ultra large scale integrated circuits and SMT technology. The key components are all low-power, long-life devices from internationally renowned brands. The overall design adopts various anti-interference technologies to improve the reliability and service life of the product.
electricity metering
Combined active total electrical energy
Freeze function
Daily freeze: stores the electrical energy at midnight every day and can store data for two months.
Data Storage
In the event of a power outage in the energy meter, all data related to settlement shall be saved for 10 years.
Display
a) Equipped with automatic loop function
b) The energy meter displays various values such as electrical energy, voltage, current, power, etc
Communication Function
The electricity meter adopts 485 communication method, which can retrieve data from the meter through 485 communication. The communication protocol follows DL/T645-2007; The communication rate of RS485 interface can be set, with standard rates of 1200bps, 2400bps, 4800bps, 9600bps, and a default value of 2400bps.
Remote cost control function
Realize the disconnection of overdue fees and payment closure through remote electricity sales system. The system has a short message reminder function for insufficient balance. The electricity bill calculation is completed in the remote electricity sales system, and the table does not store or display information related to electricity bills and prices. After strict password verification and security authentication, the electric energy meter receives instructions such as opening, allowing closing, and ESAM data reading from the remote electricity sales system.
Specification Model
| Model/Specification | Accuracy Class | Rated Voltage(V) | Maximum Current(A) | Pulse Constant(imp/kWh) |
| DDSU3579 | 1.0级 | 220 | 40 | 1200 |
| 60 | 1200 |
Basic Error
| Load Current | Power Factor | Basic Error(%) | |
| 1.0级 | 2.0级 | ||
| 0.05Ib~0.1Ib | 1.0 | ±1.5 | ±2.5 |
| 0.1Ib~Imax | 1.0 | ±1.0 | ±2.0 |
| 0.1Ib~0.2Ib | 0.5L 0.8C | ±1.5 | ±2.5 |
| 0.2Ib~Imax | 0.5L 0.8C | ±1.0 | ±2.0 |
Working Temperature Range
| The Prescribed Scope Of Work | -25℃~55℃ |
| Extreme Working Range | -25℃~65℃ |
| Storage And Transportation Limit Range | -25℃~70℃ |