IoT Smart Hot Water Meter (Cat. 1) is an intelligent water meter used for remote meter reading and control. It communicates remotely through a 4G server without the need for intermediate transmission devices, simplifying equipment installation and wiring work, realizing automatic remote meter reading of water meters, effectively avoiding the manual work of on-site meter reading by management departments, and has valve control function, making it convenient for management departments to control the usage of water meters. Each water meter works independently as a terminal, with simple maintenance and reliable operation. Compact structure with a protection level of up to IP68, suitable for various environments without debugging, ready to install and use, supported by both PC and mobile phones, can meet different customer management needs, and can set alarm water usage, overdraft water usage, etc. The calculation of water fees can be divided into tiered and non tiered water prices to meet various needs. Widely used in high-end residential areas, villas, schools, enterprises, factories, apartments, water supply and other fields.
Remote reading
Regularly and proactively report readings.
Remote valve control (optional)
Can remotely close and open valves, supports prepaid and pre order quantities, and close valves for overdue payments.
Sampling measurement
Support multiple forms of sampling methods, such as reed switches, magnetic reluctance, and other pulse sampling methods for measuring accuracy.
Infrared communication
Support direct infrared communication to set table addresses, table base numbers, and read and set various parameters of the module.
Upload mechanism
Scheduled upload: The module uploads table data to the platform at a fixed point, and the upload cycle can be set to 1-24 hours.
Manual upload: After touching the button, data can be uploaded to the platform.
Discrete upload: Discrete clock upload mechanism, automatically avoiding network congestion.
Attack status monitoring
When the watch is subjected to a strong magnetic attack, the attack status is attacked and an online alarm is triggered.
Alarm mechanism
Sampling fault alarm; Valve malfunction alarm; Low battery alarm; Low remaining amount alarm (valid prepaid status), no remaining amount valve closing alarm (valid prepaid status).
data storage
Freeze for 31 days on midnight and freeze the balance for 24 months on a monthly basis. Freeze data for cumulative usage; Record the net traffic of 48 points per day and store it.
Data Resend Mechanism
After data transmission failure, in order to ensure data delivery, the instrument will take a delayed resend operation; At the same time, daily power consumption has been limited to prevent battery undercharging caused by excessive communication.
Flexible upload frequency setting
The data upload time and frequency can be flexibly set. According to the backend settings, real-time data will be automatically retrieved when online, and the water meter will be in sleep mode when the command is not executed.
Data peak shifting mechanism
It can effectively reduce the impact on base station load, minimize waiting delay, and lower communication power consumption; The staggered interval can be set, with a default interval of 0-8.
Electrical Performance Parameters
| Project | Parameter | |
| Unit Of Measurement | 0.1 m³ | |
| Operating Temperature | Cold Water Meter:0.1℃~30℃;Hot Water Meter:0.1℃~90℃ | |
| Allow Water Pressure | 0.03 MPa~1MPa | |
| Pressure Loss Level | △p63 | |
| Flow Profile Sensitivity Level | U10,D5 | |
Climate And Mechanical Environment Safety Level | Class B | |
Electromagnetic Compatibility Level | E1 | |
| Protection Level | IP68 | |
| Transmission Parameters | Communication Protocol | 4G Internet of Things Protocol |
| Operating Frequency Band | B3、B5、B8、B20 | |
| Transmit Power | 23dBm | |
| Reception Sensitivity | -131±1dBm | |
| Quiescent Current | <9uA | |
| Communication Working Current | <130mA | |
Range Ratio And Flow Range
| Caliber(DN) | Measurement Range(Q3/Q1) | Overload Flow(Q4) | Common Traffic(Q3) | Threshold Flow(Q2) | Minimum Flow(Q1) | Minimum Reading | Maximum Reading |
| 15mm | 100 | 3.125m³/h | 2.5m³/h | 0.04m³/h | 0.025m³/h | 0.0001m³ | 99999m³ |
| 20mm | 5m³/h | 4m³/h | 0.064m³/h | 0.04m³/h | |||
| 25mm | 7.875m³/h | 6.3m³/h | 0.101m³/h | 0.063m³/h | |||
| 32mm | 12.5m³/h | 10m³/h | 0.04m³/h | 0.1m³/h | |||
| 40mm | 20m³/h | 16m³/h | 0.064m³/h | 0.16m³/h | |||
| 50mm | 31.25m³/h | 25m³/h | 0.101m³/h | 0.25m³/h |
Overall Dimensions
| Nominal Diameter | L | L1 | W | H | Threaded Connection |
| DN | mm | ||||
| 15 | 130 | 165 | 90 | 150 | G3/4B |
| 20 | 130 | 195 | 90 | 150 | G1B |
| 25 | 130 | 225 | 90 | 167 | G11/4B |
| 32 | 220 | 230 | 104 | 167 | G11/2B |
| 40 | 220 | 245 | 125 | 215 | G2B |
| 50 | 220 | 300 | 125 | 215 | G21/2B |