The IoT intelligent hot water meter consists of a base meter, NB IoT wireless communication module, and other components. Using the WoFeng narrowband IoT, the collected data such as flow rate, temperature, signal strength, etc. are transmitted to the meter reading platform through the operator's base station to achieve data collection, fault alarm, and other functions. Through Bluetooth, parameters can be set nearby. The product has wireless cable connection, easy and fast installation, as well as maintenance and replacement.
Remote meter reading based on NB network
The network structure is simple and does not require on-site debugging work such as setting up concentrators or relays;
Support cross frequency networking;
ESIM card (chip card), higher reliability
Equipped with Bluetooth supplementary channel;
Meter reading, fault analysis, and debugging can be conducted on-site;
data freeze
Freeze for 31 days at midnight and freeze the balance for 18 months per month. Freeze data for cumulative usage;
48 points of data per day, recording net traffic every half hour and storing it;
Data Resend Mechanism
After data transmission failure, in order to ensure data delivery, the instrument will take a delayed resend operation;
At the same time, daily power consumption has been limited to prevent battery undercharging caused by excessive communication;
Data peak shifting mechanism
It can effectively reduce the impact on base station load, minimize waiting delay, and lower communication power consumption; The staggered interval can be set, with a default interval of 24 hours;
Real time power monitoring
Prevent sudden voltage drops during communication that may cause the system to run away;
Event log
Time triggered: hourly recording;
Alarm triggered: sampling fault, low voltage, low remaining quantity;
Flexible data upload solution
The default state is to upload once a day; A reporting plan can be set as needed.
Dense transmission function
Upload data every set interval within the specified time, and resume normal online operation after the specified time is over;
Touch trigger method (optional): beneficial for waterproofing and demagnetization;
Alarm mechanism
Sampling fault alarm;
Low battery alarm;
Low remaining amount alarm (prepaid status is valid);
Meter reading management platform
Mobile APP production and maintenance tools: used for parameter setting during whole meter production, whole machine testing, and troubleshooting at installation sites;
| Bluetooth | Bluetooth 4.0 |
| Application Type | Management end (Android); Client (WeChat Mini Program) |
Support Operators | China Mobile, China Telecom, China Unicom |
| NB Discrete Upload Data | Randomly discretize the data upload time based on the table number, and the discrete time interval can be set. The discrete time interval shall not be less than 10 seconds. |
| Retransmission Mechanism | N Defaults To 2 Times, Adjustable Number Of Times |
| Sampling | Sampling range: (Query mode) 0.01m ³, 0.1m ³, 1m ³ (Interrupt mode) 0.001m ³, 10m ³ |
| Sampling Type: Reed Switch, Hall Sensor, Magnetoresistance | |
| Billing Method | Water Volume Mode (0.001m ³, 0.01m ³, 0.1m ³, 1m ³, 10m ³) |
| Data Reporting | Reporting Mode: Proactive Reporting, Default Is 1 Day, Time Point Can Be Set |
Debugging Mode: Bluetooth Channel Triggered; Press The Button For At Least 3 Seconds And The Light Will Remain On For 2 Seconds. The Button/Bluetooth Will Trigger A Report | |
| Contact Method | Nb Communication: Frequency Band Information Band5/Band8 |
Bluetooth Communication: Default Transmission Power: 0dBm (1.0mw) Maximum Transmission Power: 4dBm (2.5mw) Receiver Sensitivity: -96dBm Bluetooth Communication Peak Power Consumption: 6.5mA Communication Distance: (Transmission Power 0dBm, I.E. 1.0mW) Indoor: About 20 Meters Outdoor Open Space: About 60 Meters | |
| Time Calibration | At The Same Time As Nb Communication, Calibrate The Time Of The Instrument. |
Mechatronics Consistency | Support Mobile Phone Modification Of Table Base Data. |
| Battery Level | Level 8 Power, Level 4 Display On The Upper Computer |
Battery Type | 3.6V lithium argon power battery, 7000mAh Static current:<10uA Average current: ≈ 25uA |
| Battery Level 1 Low Voltage Alarm Point | 2.95V |
| Battery Level 2 Low Voltage Alarm Point | 2.75V |
Range Ratio And Flow Range
| Caliber(DN)mm | Turndown Ratio Q3/Q1 | Overload Flow Q4 | Common Traffic Q3 | Threshold Flow Q2 | Minimum Flow Q1 | Minimum Reading | Maximum Reading |
| m³ | m³ | ||||||
| 15 | 100 | 3.125 | 2.5 | 0.05 | 0.031 | 0.0001 | 99999 |
| 20 | 100 | 5.0 | 4.0 | 0.08 | 0.05 | ||
| 25 | 100 | 7.875 | 6.3 | 0.12 | 0.075 | ||
Water Meter Size Chart
| Caliber(DN)mm | Long(mm) | Wide(mm) | High(mm) | Thread(mm) | Connection Thread Length(mm) | |
| amin | bmin | |||||
| DN15 | 165 | 120 | 153 | G3/4B | 10 | 12 |
| DN20 | 195 | 120 | 158 | G1B | 12 | 14 |
| DN25 | 225 | 120 | 165 | G11/4B | 12 | 16 |
Schematic Diagram Of Water Meter Dimensions