The photoelectric direct reading hot water meter adopts photoelectric direct reading technology to directly read the character wheel data. Compared with traditional pulse water meters, it can reduce the reading error to zero and is an electronic remote water meter with zero error in electromechanical conversion in automatic meter reading systems. Adopting a low-power design, it usually does not require power supply and only needs to be powered during meter reading.
1. Compliant with the standard of Electronic Remote Water Meter (CJ/T224-2012).
2. Compliant with the national standard of "Drinking Cold Water Meter and Hot Water Meter" (GB/T778.13-2007).
3. Working power supply: DC9-15V (RS485); DC24-42V(M-BUS)。
4. Adopting advanced data encoding and verification methods, the communication reliability is high.
5. Meets the technical requirements for electromagnetic compatibility of electronic products such as EMC, ESD, EMI, etc., and is at a relatively high level in the industry.
6. Communication protocols: DL/T645, CJ/T188, MODBUS, industry standard protocols.
7. Communication interface: a) RS485 fieldbus, b) M-BUS fieldbus.
8. Communication transmission rate: 1200bps/2400bps.
9. Easy to read and able to maintain clarity for a long time.
10. Adopting photoelectric encoding non energy direct reading technology.
11. Using non-contact sensors does not affect the performance of the water meter.
12. Adopting a low-power design, power supply is only required during reading.
13. It can form a system with the upper computer to achieve remote reading and meter reading.
Main Technical Parameters
| Nominal Diameter(mm) | Accuracy Class | Common Traffic Q3 | Minimum Reading m³ | Maximum Reading m³ |
| 15 | Q3/Q1=100 Accuracy Level: Level 2 | 2.5 | 0.0001 | 9999.9999 |
| 20 | 4.0 | 0.0001 | 9999.9999 | |
| 25 | 6.3 | 0.0001 | 9999.9999 |
Signal Wiring
| Type/Line Color | Red Line | Black Line | White (Yellow) Line | Blue (Green) Line |
| 485/Bus | Positive Power Supply | Negative Power Supply | 485+ | 485- |
| Meter-Bus | Regardless Of Polarity | Regardless Of Polarity | \ | |
Analysis Of External Dimensions And Weight
| Nominal Diameter(mm) | Long(mm) | Width(mm) | High(mm) | Threaded Connection |
| 15 | 165 | 98 | 104 | G1/4B |
| 20 | 195 | 98 | 106 | G1B |
| 25 | 225 | 103 | 112 | G1’1/4B |
| 32 | 230 | 104 | 117 | G1’1/2B |
安装示意图