The photoelectric direct reading vertical intelligent water meter is used to measure the total amount of drinking water flowing through the tap water pipeline and transmit it to the secondary instrument through the 485/M-BUS bus. Built in CPU, storage chip, and 485/M-BUS communication module. Just need to supply power when collecting water meter data, read the water meter character wheel code by the photoelectric tube, generate a number through CPU judgment, and output it through the 485/M-BUS bus.
1. Compliant with the standard of Electronic Remote Water Meter (CJ/T224-2012).
2. Compliant with the national standard of "Drinking Cold Water Meter and Hot Water Meter" (GB/T778.13-2007).
3. Working power supply: DC9-15V (RS485); DC24-42V(M-BUS)。
4. Adopting advanced data encoding and verification methods, the communication reliability is high.
5. Meets the technical requirements for electromagnetic compatibility of electronic products such as EMC, ESD, EMI, etc., and is at a relatively high level in the industry.
6. Communication protocols: DL/T645, CJ/T188, MODBUS, industry standard protocols.
7. Communication interface: a) RS485 fieldbus, b) M-BUS fieldbus.
8. Communication transmission rate: 1200bps/2400bps.
9. Easy to read and able to maintain clarity for a long time.
10. Adopting photoelectric encoding non energy direct reading technology.
11. Using non-contact sensors does not affect the performance of the water meter.
12. Adopting a low-power design, power supply is only required during reading.
13. It can form a system with the upper computer to achieve remote reading and meter reading.
Main Technical Parameters
| Nominal Diameter mm | Accuracy Class | Common Traffic Q3 | Minimum Reading | Maximum Reading | 准确度等级 |
| m³/h | m³ | B级 | |||
| 15 | Q3/Q1=80﹑63、50 | 2.5 | 0.0001 | 9999 | |
| 20 | 4 | 0.0001 | 9999 | ||
| 25 | 6.3 | 0.0001 | 9999 | ||
| 32 | 10 | 0.0001 | 9999 | ||
| 40 | 16 | 0.0001 | 9999 | ||
Signal Wiring
| Type/Line Color | Red Line | Black Line | White (Yellow) Line | Blue (Green) Line |
| 485/Bus | Positive Power Supply | Negative Power Supply | 485+ | 485- |
| Meter-Bus | Regardless Of Polarity | Regardless Of Polarity | \ | |
Analysis Of External Dimensions And Weight
| Model | Nominal Diameter | Long | Width | High | Threaded Connection |
| mm | |||||
| LXSY-15E | 15 | 165 | 98 | 104 | G1/4B |
| LXSY-20E | 20 | 195 | 98 | 106 | G1/B |
LXSY-25E | 25 | 225 | 103 | 112 | G1’1/4B |
| LXSY-32E | 32 | 230 | 104 | 117 | G1’1/2B |
| LXSY-40E | 40 | 245 | 124 | 147 | G2B |
Installation Wiring Diagram