智能水表 智能电表 超声波水表 远程抄表系统 水电远程预付费系统 水电监测支付管理平台 能耗监测管理系统 智慧能源管理系统 智慧公寓管理平台 智慧照明管理系统 智能空调节能控制器 宿舍水电控管理系统 水控机管理平台

Single-Phase Electronic Ammeter (Rail-Mounted)-DDSU3579
  • Single-Phase Electronic Ammeter (Rail-Mounted)-DDSU3579
  • 1/1
  • Single-Phase Electronic Ammeter (Rail-Mounted)-DDSU3579

Single-Phase Electronic Ammeter (Rail-Mounted)-DDSU3579

share
WeChat
Sina Weibo
QQ
QQ space
Douban
Baidu Post Bar
电压 220V
额定频率 50Hz
规定工作温度 -25℃~+55℃
极限工作温度 -30℃~+60℃
相对湿度 ≤85%
外型 90mmx72mmx75mm
马上咨询
在线询价
产品简介功能简介技术参数

Single phase electronic watt hour meter (guide rail) DDSU3579 has a metering product that accurately measures positive and negative active electric energy. It adopts advanced special two-way electric energy metering digital circuit chip and SMT manufacturing process, highly integrated design and multiple anti-interference designs such as anti-static, lightning protection, transient interference suppression, etc. The key components are low power consumption, long-life components of international famous brands, anti deformation, anti-corrosion, anti-aging, good insulation and sealing performance. The key components include dedicated measurement chips CPU、 Crystal oscillator, circuit board, power transformer, etc. Its characteristics are bidirectional power measurement and counting, anti-theft, high precision, high reliability, high overload, low power consumption, light weight, low cost, and optical isolation of communication interface.

●With forward and reverse active electrical energy and combined active electrical energy measurement, the combination mode word is fixed as forward active + reverse active;

●In the event that the power supply of the electricity meter is cut off, the data in the meter can be stored for 10 years;

●RS485 communication interface

The communication baud rate can be set, and the standard rate is 1200bps, 2400bps, 4800bps, 9600bps; the default baud rate designed by RS485 interface is 2400bps;

The communication protocol of the electricity meter is in accordance with DL/T 645-2007 and its filing documents;

The anti-interference performance of RS485 communication interface meets the requirements of DL/T 614-2007;

The RS485 communication interface should be effectively electrically isolated from the internal circuit of the electricity meter, and there should be failure protection measures;

●Electrical energy pulse output

It has optical pulse output and electrical pulse output that are directly proportional to the measured electrical energy (active);

The optical pulse output adopts ultra-bright, long-life LED devices, and the pulse width: 80ms±20ms;

The electric pulse output has electrical isolation and can be collected from the front;

●The total active power, current, voltage and power factor can be measured;

●Remotely control the power-on and power-off of the meter through software;

Parameter Description


Project

Technical Parameter

Normal Working Voltage

0.8~1.2 Rated Voltage

Maximum Working Voltage

0.7~1.3 Rated Voltage

Insulation Voltage

≥4000VAC

Power Consumption

≤1.0W

Working Temperature Range

-25℃~+55℃

Extreme Operating Temperature

-25℃~+65℃

Average Annual Humidity

≤75%

Storage And Transportation Temperature

-25℃~+70℃

External Size

90mm×72mm×36mm


Specification And Model


Specifications/ModelsAccuracy Level

Rated Voltage(V)

Maximum Current (A)

Pulse Constant(imp/kWh)

DDSU3579

1.0级

3×220/380

60

1200


Technical Indicators


Load Current

Power Factor

Basic Error(%)

Level 1.0

0.05Ib~0.1Ib

1.0

±1.5

0.1Ib~Imax

1.0

±1.0

0.1Ib~0.2Ib

0.5L

±1.5

0.2Ib~Imax

0.5L

±1.0




电话咨询:0755-86570056
QQ咨询:1469172190
微信客服