HeZhongZhiDa IoT smart water meter, wireless smart water meter consists of remote transmission base meter, NB-IOT wireless communication module and other components. The NB-IOT wireless communication module automatically sends users' daily (customizable) water usage data directly to the cloud data server through the NB-IOT base station, and the meter end communicates directly with the backend server; By utilizing public networks, there is no need to build one's own network. The network structure is simple, and the product structure is easy to maintain and replace. Wireless cable connections make installation convenient and fast.
1.Advanced structural design, electromechanical separation structure, easy maintenance in the later stage.
2.ER26500 high-capacity battery with a battery life of over 6 years.
3.Stable measurement, using Hall pulse measurement.
4.IP68 protection, double sealed with structure and glue filling.
5.Using organic glass, it has good anti freezing performance.
6.Abnormal alarm function, active alarm for battery failure and sensor abnormality.
Electrical Performance Parameters
| Electrical Performance Parameters | ||
| Power Consumption | Static Current Power Consumption | ≤20µA |
| Maximum Wireless Current Transmission Power Consumption | =220mA 左右 | |
| Wireless Performance Parameters | Maximum Output Power | -129dBm±1dB |
| Receiving Sensitivity | 23dBm±2dB | |
| Frequency Band Information | 850MHz/900MHz/800MHz/700MHz | |
| Supply Electricity | 3.6V Lithium Battery | Design Lifespan Of Over 10 Years |
| 8.5AH | ||
| Sampling Method | Hall Sensor, Dual Pulse | Pointer Sampling At 0.01, Forward To Add, Reverse To Subtract |
| Data Escalation | Working Mode | Proactively Report, Time Can Be Set |
| Debug Mode | Trigger Reporting, The Trigger Point Is Triggered By A Magnet | |
Range Ratio And Flow Range
| Nominal Diameter(DN) | Turndown Ratio | Overload FlowQ4 | Common TrafficQ3 | Threshold FlowQ2 | Minimum FlowQ1 | Minimum Reading | Maximum Reading |
| mm | Q3 /Q1 | m³/h | m³ | ||||
| 15 | 100 | 3.125 | 2.5 | 0.05 | 0.031 | 0.0001 | 99999 |
| 20 | 100 | 5.0 | 4.0 | 0.08 | 0.05 | ||
| 25 | 100 | 7.875 | 6.3 | 0.12 | 0.075 | ||
| 32 | 100 | 12.5 | 6.3 | 0.1 | 0.063 | ||
| 40 | 100 | 20 | 16 | 0.256 | 0.16 | ||
Installation Diagram And Dimensions
Nominal Diameter(mm) | Long(mm) | Wide(mm) | High(mm) | Thread(mm) | Connection Thread Length(mm) | |
amin | bmin | |||||
| DN15 | 165 | 86 | 148 | G3/4B | 10 | 12 |
| DN20 | 195 | 86 | 148 | G1B | 12 | 14 |
| DN25 | 225 | 86 | 148 | G11/4B | 12 | 16 |
| DN32 | 230 | 100 | 195 | G11/2B | 14 | 26 |
| DN40 | 245 | 125 | 156 | G2B | 15 | 23 |