智能水表 智能电表 超声波水表 远程抄表系统 水电远程预付费系统 水电监测支付管理平台 能耗监测管理系统 智慧能源管理系统 智慧公寓管理平台 智慧照明管理系统 智能空调节能控制器 宿舍水电控管理系统 水控机管理平台

Single Phase Cost Controlled Multi Circuit Energy Meter - DZY3579-Z
  • Single Phase Cost Controlled Multi Circuit Energy Meter - DZY3579-Z
  • 1/1
  • Single Phase Cost Controlled Multi Circuit Energy Meter - DZY3579-Z

Single Phase Cost Controlled Multi Circuit Energy Meter - DZY3579-Z

share
WeChat
Sina Weibo
QQ
QQ space
Douban
Baidu Post Bar
电压 220V
额定频率 50Hz
规定工作温度 -25℃~+65℃
极限工作温度 -40℃~+70℃
相对湿度 ≤95%
外型 160mm×112mm×58mm
标准 Q/GDW354-2009、Q/GDW355-2009、Q/GDW365-2009
马上咨询
在线询价
产品简介功能简介技术参数

Single phase fee controlled multi circuit energy meter - DZY3579-Z is a product specially customized for the campus market. With the campus prepaid system, it can realize remote recharge and electricity management for student dormitories, classrooms, offices and other areas.

1. Malignant load identification.


2. Multi loop metering function.


3. Prepaid management: Remote recharge and refund of electricity meters through a prepaid system.


4. Insufficient balance alarm: When the voltage of the electricity meter exceeds the set value, it will automatically trip to protect the electrical equipment.


5. When the voltage returns to normal, release the trip.


6. Insufficient balance trip: The meter trips when the balance is insufficient, and the trip methods are remote trip command and active meter trip.


7. Power protection and release of power protection: In the power protection state, all trips fail and the electricity meter is forced to close; After releasing the power protection state, the electricity meter returns to its normal tripping state.

Parameter Description


Project

Technical Specifications

Accuracy Class

Merit: Level 1, Level 2

Starting Working Current

    ≤0.4%Ib(Direct Access Type)

Voltage Line Power Consumption

    Non Communication State ≤ 0.5W, Communication State ≤ 3W

Power Consumption Of Current Circuit

    ≤1VA

Clock Accuracy(23℃)

    ≤ 0.5 seconds/day

Normal Operating Temperature

    -25℃~+65℃

Extreme Working Temperature

    -40℃~+70℃

Storage And Transportation Temperature

    -40℃~+70℃

Relative Humidity

    ≤95%

External Dimensions

    160mm×112mm×71mm


Specification Model


Model/SpecificationAccuracy ClassRated Voltage(V)Maximum Current(A)Pulse Constant(imp/kWh)
DDZY3579-Z2.0220601200


Technical Indicators


Load CurrentPower FactorBasic Error(%)
Level 1.0Level 2.0
0.05Ib~0.1Ib1.0±1.5±2.5
0.1Ib~Imax1.0±1.0±2.0
0.1Ib~0.2Ib0.5L 0.8C±1.5±2.5
0.2Ib~Imax0.5L 0.8C±1.0±2.0



电话咨询:0755-86570056
QQ咨询:1469172190
微信客服